Railway Signal Cable

Railway Signal Cable


Index>Railway Cable: >Railway Signal Cable


内容介绍


cable introduction


Usage
It is used in rated voltage up to AC 500V or DC 1000V control circuit as railway signal transmission and communication,audio signal or automatism signal,the multi-sheath railway signal cable has screen character,which is suitable for laying in electrified railways or others field under strong Interference.
Operating Characteristics:
1.1 The ambient temperature :-40 deg.~+60 deg.
1.2 the operating temperature should not be higher than +70deg.
1.3 The ambient temperature under installation ,PVC sheath cable should not be below 0 deg.,PE sheath cable should not be below -20 deg.
1.4 mini bending radius: non-armoured cable>=10 times of the cable diameter armoured cable>=12 times of the cable diameter
1.5 multi-sheath train signal cable screening factors ≤0.8 aluminium sheath train signal cable screening factors ≤0.3

Types and Description

TYPES

Name

Installation Scope

Specification (core)

PTYV

PE insulation,PVC sheath,railway signal cable


For laying in tunnel, cable trench, or direct in ground, able to bear certain external mechanical forces

4、6、8、9、 12、14、16、19、21、24、28、30、33、37、42、44、48、52、56、61

PTYY

PE Insulation,PE sheath railway signal cable

PTY22


PE insualtion,steel tape armour,PVC outer-sheath railway signal cable


For laying in tunnel, cable trench, or direct in ground, able to bear larger external mechanical forces

PTY23


PE insulation steel tape armour PE outer-sheath railway signal cable

PTYA22


PE insulation comprehensive sheath steel tape armour PVC outer-sheath railway signal cable

PTYA23


PE insulation comprehensive sheath steel tape armour PE outer-sheath railway signal cable

PTYL22


PE insulation ,Aluminium sheath ,steel tape armour, PVC outer-sheath railway signal cable

PTYL23


PE insulation, aluminium sheath ,steel tape armour, PE outer-sheath railway signal cable

Types Code Instruction


Code


Instruction


Code


Instruction

PT Railway Signal Cable
22 Double Steel Tape Armour PVC Outer-sheath
SPT Railway digital signaling cable
23 Double Steel Tape Armour PE Outer-sheath
YW physically foamed skin-foam-skin polyolefin insultaion
03 non-armour PE Outer-sheath
Y polyolefin insultaion or Sheath
H Cold Resistant
P Inner Shield (Digital Cable)
DWZR low somke halogen free &flame retardant
P Copper wire braided sreen (Data transmission cable for balise)
-FBY termite resistant type
L Aluminium Sheath
-GP high-performance shielding type
A Comprehensive Sheath
PJ Axle Counter Signaling Cable
HE Long distance symmetric cable
LEU.BS Data transmission cable for balise

Main Cable Technical Properties

Ser.No.
Item
Unit
Index
Conversion Formula
1
1.1
1.2
DC resistant 20℃

DC resistant for each conductor

Resistance unbalance of conductor working pair
Ω/km
≤23.5
≤2%
L/1000
2
Insulation resistant
MΩ·km
≥3000
1000/L
3
3.1
3.2
3.3
Capacitance
Twisted pair working Capacitance
Star quad working Capacitance

Capacitance between each insulated wire and other insulated wire connecting to ground
nF/km
≤70
≤50
≤100
L/1000
4
4.1
4.2

Capacitance coupling coefficient
K1 Average value
Maximum value
K9~K12 Average value
Maximum value

For 4-core quad, k1 is the maximum value
pF/500m
≤100
≤330
≤120
≤230
L/500
L/500
5

Capacitance unbalance to earth
ea1 ea2 Average Value

Maximum Value
br>For 4-core cable, ea1、ea2are the maximum value
nF/500m
≤330
≤1300
L/500
6
6.1
6.2
Dielectric voltage withstand
Time of Duration 2min
Between Cores
Cores versus others earthing cores
1000
1800
——

Cable OuterDiameter and Weight

Specifiaction
PTYV、PTYY
PTY22、PTY23
OuterDimeter
Weight (kg/km )
OuterDimeter(mm)
kg/km<
Weight/div>
4
6
8
9
12
14
16
19
21
24
28
30
33
37
42
44
48
52
56
61
8.8
11.8
12.8
12.8
14.5
14.5
16.1
16.1
16.1
17.8
19.8
19.8
19.8
22.1
23.0
23.0
25.1
25.1
26.3
26.3
76
112
137
147
185
204
232
261
280
319
365
385
414
464
518
537
588
627
672
720
12.2
15.2
16.2
16.2
19.0
19.0
20.6
20.6
20.6
22.3
23.7
23.7
23.7
26.0
26.9
26.9
29.2
29.2
31.6
31.6
115
235
270
280
335
354
397
426
446
502
563
582
611
684
747
766
839
878
1207
1255

Specification
PTYA22、PTYA23
PTYL22、PTYL23
OuterDimeter(mm)
Weight (kg/km)
Outer Diameter (mm)
Weight(kg/km)
4
6
8
9
12
14
16
19
21
24
28
30
33
37
42
44
48
52
56
61
15.7
17.6
18.6
18.6
20.3
20.3
21.9
21.9
21.9
23.6
25.0
25.0
25.0
27.3
28.4
28.4
31.9
31.9
33.1
33.1
259
295
333
342
403
422
467
495
515
577
642
661
690
769
834
854
948
987
1331
1379
21.8
24.0
24.0
24.0
26.0
26.0
28.2
28.2
28.2
31.4
31.4
31.4
31.4
34.6
34.6
34.6
36.6
36.6
38.8
38.8
561
666
731
741
848
867
928
956
976
1091
1171
1190
1219
1383
1469
1488
1618
1656
1736
1784

able Structure Drawing

Delivery length
Cable with length 500m and over do not less than 50% of total delivery length in Order, and with length less than 50m~250m not more than 5% of total delivery length.
Tolerance of metering length do not exceed ±0.5%.


PreviousPage Next    Page

14 person contacting us now




Contact Information

Company Name:CHINA LUBAO CABLE GROUP CO.,LTD.

Telephone:0086-13865965950

Fax:0086-551-64266536

Email:sales@lubaocables.com