Cable for Railway Vehicles

Cable for Railway Vehicles


Index>Railway Cable: >Cable for Metro/Railway Vehicles


内容介绍


cable introduction


EPR Rubber Insulated Cable for Railway Vehicles

Application

This cable is intended for power and control system on railway vehicles or other vehicles.

Reference Standards

  • »»GB12528.4-90    
  • »»UL 44

Service Property Parameter

Main Parameter Performance Index
AC Rated voltage 750V,1500V,3000V
Long time permisssible maximum operating temperature For DCEH/3, 70℃
For DCEH/3-100,100℃
Cables can be used in fields such as polluted by mineral oil and fuel oil.
Laying permitted bending radius Overall diameter of cable(D) less than 20mm ≥3D (D: Cable diameter.mm)
Overall diameter of cable(D) more than 20mm ≥5D (D: Cable diameter.mm)


Type and Description


Type Description
DCEH/3 Copper wire EPR insulated CPE/CSP sheathed cable for railway vehicles
DCEH/3-100 Copper wire heat-resisting EPR insulated CPE/CSP sheathed cable for railway vehicles

Cable Specification


Type Rated voltage No.of cores Nominal section Construction sizw sheet
DCEH/3 750V
1500V
3000
1
1
1
0.5-300
1-300
2.5-300
Table1
Table2
Table3
DCEH/3-100 750V
1500V
3000
1
1
1
0.5-300
1-300
2.5-300
Table1
Table2
Table3

 

Back Top


XLPO Rubber Insulated Cable for Railway Vehicles

Application

This cable is intended for power and control system rated a.c. voltage up to and including 3kV on railway vehicles or other vehicles.

Reference Standards

  • »»GB12528.11-2003

Service Property Parameter

Main Parameter Performance Index
AC Rated voltage 750V,1500V,3000V
Long time permisssible maximum operating temperature
For WDZ-DCYJ-125,WDZ-DCYJ/B125
For WDZ-DCYJ/B150

125℃
150℃
Min. application ambient temperature:
For WDZ-DCYJ-125
For WDZ-DCYJ/B125,WDZ-DCYJ/B150

-40℃
-60℃
Permited Operating condition
WDZ-DCYJ-125 Oil pollution condition
WDZ-DCYJ/B-125,WDZ-DCYJ/B-150 use in harsh environments with various types of oil contamination and non-high-concentration acid or alkali contamination.
Laying permitted bending radius Overall diameter of cable(D) less than 20mm ≥3D
Overall diameter of cable(D) more than 20mm ≥5D

Type and Description


Type Rated voltage(V) Description
WDZ-DCYJ-125 500,750,
1500,3000
Copper wire heat-resisting 125°C XLPO insulated halogen-free low-smoke flame-retardant cable for railway vehicles
WDZ-DCYJ/B-125 750 Copper wire heat-resisting 125°C high-strengthened thin-walled XLPO insulated halogen-free low-smoke flame-retardant cable for railway vehicles
WDZ-DCYJ/B-150 750 Copper wire heat-resisting 150°C high-strengthened thin-walled XLPO insulated halogen-freelow-smoke flame-retardant cable for railway vehicles


Cable Specification and construction


omit

 

Back Top


NR+SBR Insulated Cable for Railway Vehicles

Application

This cable is intended for power and control systemrated a.c. voltage up to and including 1.5kV on railway vehicles or other vehicles.

Reference Standards

  • »»GB12528.2-90

Service Property Parameter

Main Parameter Performance Index
Rated voltage AC 750V,1500V
1.5 times of AC
Permited Operating condition used in fields polluted by mineral oil But without fuel oil pollution.
Long time permisssible maximum operating temperature 70℃
Laying permitted bending radius Overall diameter of cable(D) less than 20mm ≥3D
Overall diameter of cable(D) more than 20mm ≥5D


Type and Description


Type Type Description
DCXF/2 750,1500 Copper wire NR+SBR insulated PCP rubber sheathed cable for railway vehicles


Cable Specification


Omit

 

Back Top

CSP Rubber Insulated Cable for Railway Vehicles

Application

This cable is intended for power and control systemrated a.c. voltage up to and including 750V on railway vehicles or other vehicles.



Reference Standards

  • »»12528.3-90

Service Property Parameter

Main Parameter Performance Index
Rated voltage 750V
Long time permisssible maximum operating temperature For DCH/3, 70℃
For DCH/3-100, 100℃
Permited Operating condition used in fields such as polluted by mineral oil and fuel oil .
Laying permitted bending radius Overall diameter of cable(D) less than 20mm ≥3D
Overall diameter of cable(D) more than 20mm ≥5D


Type and Description


Type Description
DCH/3 Copper conductor CSP insulated cable for railway vehicles
DCH/3-100 Copper conductor heat-resisting 100℃ CSP insulated cable for railway vehicles


Cable Specification


Conductor nominal cross
section(mm²)
Conductor
specification
Insulation nominal cross
section(mm)
Average overall
diameter
0.5 A 1.0 3.4
B 1.0 3.4
0.75 A 1.0 3.8
B 1.0 3.8
1.0 A 1.2 4.4
B 1.2 4.4
1.5 A 1.2 4.7
B 1.2 4.7
2.5 A 1.2 5.2
B 1.2 5.2
4 A 1.2 6.0
B 1.2 6.0
6 A 1.2 7.4
B 1.2 7.4
10 A 1.4 9.0
B 1.4 9.0
16 A 1.4 10.5
B 1.4 10.0
25 A 1.6 12.5
B 1.6 12.5
35 A 1.6 14.0
B 1.6 14.0
50 A 1.8 16.5
B 1.8 16.0
70 A 1.8 18.5
B 1.8 18.0
95 A 2.0 20.5
B 2.0 20.5
120 A 2.0 22.5
B 2.0 22.5
150 A 2.2 25.5
B 2.2 25.0
185 A 2.4 27.5
B 2.4 27.5
240 A 2.6 31.0
B 2.6 31.0
300 A 2.8 34.0
B 2.8 34.0
```

 

Back Top