Cable for Railway Vehicles

内容介绍

EPR Rubber Insulated Cable for Railway Vehicles
Application
This cable is intended for power and control system on railway vehicles or other vehicles.
Reference Standards
- »»GB12528.4-90
- »»UL 44
Service Property Parameter
| Main Parameter | Performance Index |
|---|---|
| AC Rated voltage | 750V,1500V,3000V |
| Long time permisssible maximum operating temperature |
For DCEH/3, 70℃ For DCEH/3-100,100℃ |
| Cables can be used in fields | such as polluted by mineral oil and fuel oil. |
| Laying permitted bending radius |
Overall diameter of cable(D) less than 20mm ≥3D (D: Cable diameter.mm) Overall diameter of cable(D) more than 20mm ≥5D (D: Cable diameter.mm) |
Type and Description
| Type | Description |
| DCEH/3 | Copper wire EPR insulated CPE/CSP sheathed cable for railway vehicles |
| DCEH/3-100 | Copper wire heat-resisting EPR insulated CPE/CSP sheathed cable for railway vehicles |
Cable Specification
| Type | Rated voltage | No.of cores | Nominal section | Construction sizw sheet |
| DCEH/3 |
750V 1500V 3000 |
1 1 1 |
0.5-300 1-300 2.5-300 |
Table1 Table2 Table3 |
| DCEH/3-100 |
750V 1500V 3000 |
1 1 1 |
0.5-300 1-300 2.5-300 |
Table1 Table2 Table3 |
Back Top
XLPO Rubber Insulated Cable for Railway Vehicles
Application
This cable is intended for power and control system rated a.c. voltage up to and including 3kV on railway vehicles or other vehicles.
Reference Standards
- »»GB12528.11-2003
Service Property Parameter
| Main Parameter | Performance Index |
|---|---|
| AC Rated voltage | 750V,1500V,3000V |
|
Long time permisssible maximum operating temperature For WDZ-DCYJ-125,WDZ-DCYJ/B125 For WDZ-DCYJ/B150 |
125℃ 150℃ |
|
Min. application ambient temperature: For WDZ-DCYJ-125 For WDZ-DCYJ/B125,WDZ-DCYJ/B150 |
-40℃ -60℃ |
| Permited Operating condition | |
| WDZ-DCYJ-125 | Oil pollution condition |
| WDZ-DCYJ/B-125,WDZ-DCYJ/B-150 | use in harsh environments with various types of oil contamination and non-high-concentration acid or alkali contamination. |
| Laying permitted bending radius |
Overall diameter of cable(D) less than 20mm ≥3D Overall diameter of cable(D) more than 20mm ≥5D |
Type and Description
| Type | Rated voltage(V) | Description |
| WDZ-DCYJ-125 |
500,750, 1500,3000 |
Copper wire heat-resisting 125°C XLPO insulated halogen-free low-smoke flame-retardant cable for railway vehicles |
| WDZ-DCYJ/B-125 | 750 | Copper wire heat-resisting 125°C high-strengthened thin-walled XLPO insulated halogen-free low-smoke flame-retardant cable for railway vehicles |
| WDZ-DCYJ/B-150 | 750 | Copper wire heat-resisting 150°C high-strengthened thin-walled XLPO insulated halogen-freelow-smoke flame-retardant cable for railway vehicles |
Cable Specification and construction
Back Top
NR+SBR Insulated Cable for Railway Vehicles
Application
This cable is intended for power and control systemrated a.c. voltage up to and including 1.5kV on railway vehicles or other vehicles.
Reference Standards
- »»GB12528.2-90
Service Property Parameter
| Main Parameter | Performance Index |
|---|---|
| Rated voltage |
AC 750V,1500V 1.5 times of AC |
| Permited Operating condition | used in fields polluted by mineral oil But without fuel oil pollution. |
| Long time permisssible maximum operating temperature | 70℃ |
| Laying permitted bending radius |
Overall diameter of cable(D) less than 20mm ≥3D Overall diameter of cable(D) more than 20mm ≥5D |
Type and Description
| Type | Type | Description |
| DCXF/2 | 750,1500 | Copper wire NR+SBR insulated PCP rubber sheathed cable for railway vehicles |
Cable Specification
Back Top
CSP Rubber Insulated Cable for Railway Vehicles
Application
This cable is intended for power and control systemrated a.c. voltage up to and including 750V on railway vehicles or other vehicles.
Reference Standards
- »»12528.3-90
Service Property Parameter
| Main Parameter | Performance Index |
|---|---|
| Rated voltage | 750V |
| Long time permisssible maximum operating temperature |
For DCH/3, 70℃ For DCH/3-100, 100℃ |
| Permited Operating condition | used in fields such as polluted by mineral oil and fuel oil . |
| Laying permitted bending radius |
Overall diameter of cable(D) less than 20mm ≥3D Overall diameter of cable(D) more than 20mm ≥5D |
Type and Description
| Type | Description |
| DCH/3 | Copper conductor CSP insulated cable for railway vehicles |
| DCH/3-100 | Copper conductor heat-resisting 100℃ CSP insulated cable for railway vehicles |
Cable Specification
|
Conductor nominal cross section(mm²) |
Conductor specification |
Insulation nominal cross section(mm) |
Average overall diameter |
| 0.5 | A | 1.0 | 3.4 |
| B | 1.0 | 3.4 | |
| 0.75 | A | 1.0 | 3.8 |
| B | 1.0 | 3.8 | |
| 1.0 | A | 1.2 | 4.4 |
| B | 1.2 | 4.4 | |
| 1.5 | A | 1.2 | 4.7 |
| B | 1.2 | 4.7 | |
| 2.5 | A | 1.2 | 5.2 |
| B | 1.2 | 5.2 | |
| 4 | A | 1.2 | 6.0 |
| B | 1.2 | 6.0 | |
| 6 | A | 1.2 | 7.4 |
| B | 1.2 | 7.4 | |
| 10 | A | 1.4 | 9.0 |
| B | 1.4 | 9.0 | |
| 16 | A | 1.4 | 10.5 |
| B | 1.4 | 10.0 | |
| 25 | A | 1.6 | 12.5 |
| B | 1.6 | 12.5 | |
| 35 | A | 1.6 | 14.0 |
| B | 1.6 | 14.0 | |
| 50 | A | 1.8 | 16.5 |
| B | 1.8 | 16.0 | |
| 70 | A | 1.8 | 18.5 |
| B | 1.8 | 18.0 | |
| 95 | A | 2.0 | 20.5 |
| B | 2.0 | 20.5 | |
| 120 | A | 2.0 | 22.5 |
| B | 2.0 | 22.5 | |
| 150 | A | 2.2 | 25.5 |
| B | 2.2 | 25.0 | |
| 185 | A | 2.4 | 27.5 |
| B | 2.4 | 27.5 | |
| 240 | A | 2.6 | 31.0 |
| B | 2.6 | 31.0 | |
| 300 | A | 2.8 | 34.0 |
| B | 2.8 | 34.0 |
Back Top
0 person contacting us now
Contact Information
Company Name:CHINA LUBAO CABLE GROUP CO.,LTD.
Telephone:0086-13865965950
Fax:0086-551-64266536
Email:sales@lubaocables.com
Address:Wenzhong Road,Yaohai Indrustrial Park,Hefei City,China